YBBP series flameproof frequency control and timing three-phase asynchronous motors
Category:
- Description
- Technical parameter
- Installation and size
- Anatomical drawing
- Bearing specifications
-
- Commodity name: YBBP series flameproof frequency control and timing three-phase asynchronous motors
- Commodity ID: 1104100958699933696
YBBP series flameproof frequency control and timing three-phase asynchronous motors, its explosion-proof performance meets the requirements ofb GB38361-2010" Explosive environment Part 1: General requirements of equipment" and GB38362-201 0 "Explosive environment Part 2: Equipment protected by flameproof endosure"d". As general driving force, are suitable for flammable gases containing certain components or explosive mixtures of steam and air. The motor can be matched with all kinds of frequency conversion devices at home and abroad. The speed control system consists of energy-saving economy, wide speed range, strong overload capacity and good low-speed performance. It can be widely used in petroleum, chemical and other industries.
The motor is equipped with a separate flameproof axial fan as the cooling air source to ensure the temperature rise of the motor at low frequencies.
The motor can also be equipped with auxiliary equipment such as winding temperature sensor, bearing temperature sensortemperature transmitter and heater according to user needs.Explosion-proof marks
The explosion-proof marks are Ex dll AT4 Gb and Ex dllbT4 Gb.
Structure
The degrees of protection:IP55;
Cooling type:IC411;
Insulation dass:F;
The power below 55 kW is Y connection,
and above 55 kW is 0 connection.Operation Conditions
Rated voltage:380V,660V,380/660V;
Rated Frequency:50Hz;
Operation mode:S1(continuous duty);
Less than 1000 meters above elevation;
The variation of temperature to the season shall be kept within-15-+40 t; (indoor type);
Highest average R.H. in the environment:when the monthly averagetemperature is not exceeding 25C,the average humidity should notbe more than 90%.Frequency conversion range
2P:When nominal power is less than 45kW, the constant torque range is 5-50Hz and the constant power range is 50-10OHz;When nominal power is above 45kW, the constant torque range is 5-501z and the constant power range is 50-60Hz;
4P:When nominal power is less than 200kW, the constant torque range is 5-50Hz and the constant power range is 50-100Hz;When nominal power is above 200kW, the constant torque range is 5-50Hz and the constant power range is 50-60Hz;
6/8/10P:The constant torque range is 5-50Hz and the constant power range is 50-100Hz. -
-
-
-
Frame Size POLES Explosion-proof Motor Driving end Non driving end 80 2.4.6.8 6204-2RZ 90 2.4.6.8 6205-2RZ 100 2.4.6.8 6206-2RZ 112 2.4.6.8 6206-2RZ 132 2.4.6.8 6208-2RZ 160 2 6209-2RZ 6209-2RZ 160 4.6.8 6309-2RZ 180 2 6211-2RZ 6211-2RZ 180 4.6.8 6311-2RZ 200 2 6212-2RZ 6212-2RZ 200 4.6.8 6312-2RZ 225 2 6312-2RZ 6312-2RZ 225 4.6.8 6313-2RZ 250 2 6313 6313 250 4.6.8 6314 280 2 6314 6314 280 4.6.8 6317 315 2 6316(80*170*39) 315 4.6.8.10 6319 355 2 6322
Related products